"Inclinometer Chain - Differential Deformation" Function Block

Evaluation of data from an inclinometer chain - calculation of the differential deformation per chain link by by difference formation compared to reference measurement, scaled with step size.

  • Input channels:

    • Up to 15 channels for the incline values of the inclinometer chain links.
      If the inclinometer chain has fewer than 15 links, leave the corresponding input channels unspecified (select drop-down menu item "-").

  • Parameters:

    • DISPLAY POSITION-AXIS ACCORDING TO
      Dropdown menu to specify the orientation of the inclinometer chain: Orientation in "X", "Y" or "Z" direction.

    • COORDINATES VALUE OF REFERENCE POINT
      Text field to enter the coordinates value of the reference point. Used for the orientation of the inclinometer chain as x, y or z coordinate of the reference point, depending on the selection.

    • REFERENCE SYSTEM
      Dropdown menu to specify whether the inclinometer chain reference point is at the head or foot of the chain.
      Possible choices: "Fixed foot point (default)" and "Fixed head point".

    • INVERT SIGNS
      Checkbox to set whether the reference measured values are subtracted from the measured values to form the deformation differences (default checkbox not selected), or - vice versa - the measured values are subtracted from the reference measured values (compare calculation instruction below).

  • Output channels:

    • Up to 15 output channels for the differential deformations of the chain links of one inclinometer chain.
      Each output channel corresponds to the input channel in the same position.

    • One output channel for the reference point (always created).

  • Calculation instruction per measurement time for chain link i:
    Differential deformation diffDef i = (m i – m 0_i) * s i * f, with

    • m i: Incline measured value for chain link i at current measurement time T

    • m 0_i: Reference measured value for chain link i at time point T ("zero measurement")

    • s i: Step size

    • f: -1, if the "Invert signs" parameter checkbox is checked, otherwise 1.