What is a reference measurement?
Applies to: TIME-VALUE MEASUREMENTSGEODETIC MEASUREMENTS
One or more points in time can be set as reference measurements for each measuring point. When a reference measurement is created, the measured value for this point in time is determined and recorded for all channels of a measuring point. If no measured value is found within a specified tolerance interval, the reference value can also be entered manually.
Once a reference measurement has been defined, the delta function block can be used to determine the differences between the respective channels and the reference measurement.