Number | Notification |
|---|
100 | Station <StationName>: Manufacturer <Manufacturername> is not supported |
204 | Upload of measurements failed. Error {0} |
205 | Station <StationName>: Measuring point group <Measuringpointgroupname> measurement started |
206 | Station <StationName>: Measurement point group <Measuringpointgroupname> measurement complete |
207 | Station <StationName>: Measurement point group <Measuringpointgroupname> Error in measurement preparation |
208 | Station <StationName>: Measurement point group <Measuringpointgroupname> Measurement failed |
209 | Station <StationName>: Measurement point group <Measuringpointgroupname> Measurement canceled |
210 | Station <StationName>: Measurement point group <Measuringpointgroupname> Start of measurement failed |
220 | Station <StationName>: Measurement point group <Measuringpointgroupname> Measurement <Measurementdate> uploaded |
221 | Station <StationName>: Measurement point group <Measuringpointgroupname> Upload of <Measurementdate> failed |
|
|
300 | Station <StationName>: <Number> |
301 | Station <StationName>: Device could not be loaded |
302 | Station <StationName>: Station could not be loaded |
303 | Station <StationName>: Station deleted by a user |
304 | Station <StationName>: Measuring point <Measuringpointnumber.>: <Number> |
305 | Station <StationName>: New stationing |
|
|
400 | Station <StationName>: Error in measurement in Phase 0: <Number> |
401 | Station <StationName>: Error in measurement in Phase 1: <Number> |
402 | Station <StationName>: Error in measurement in Phase 2: <Number> |
403 | Station <StationName>: Error in measurement in Phase 3: <Number> |
410 | Station <StationName>: Measurement canceled |
420 | Station <StationName>: Error in fixpoint group |
421 | Station <StationName>: Error in fixpoint group during remeasurement |
422 | Station <StationName>: Error in measuring point group |
430 | Station <StationName>: New stationing with <Quantity> of fixpoints as starting point |
431 | Station <StationName>: Messe <Quantity> Fixpunkte |
432 | Station <StationName>: Messe <Quantity> Messpunkte |
433 | Station <StationName>: Fixpoint <Number> cannot be measured |
434 | Station <StationName>: At least 3 measurable fixpoints required (only <Quantity> found) |
435 | Station <StationName>: Fixpoint <Number> remeasured due to excessive deviation |
436 | Station <StationName>: At least 3 measurable and valid fixpoints required (only <Quantity> found) |
437 | Station <StationName>: Fixpoint <Number> discarded due to excessive deviation |
438 | Station <StationName>: Takeover of last measurement for <Quantity> fixpoints |
439 | Station <StationName>: Takeover of last measurement for <Quantity> fixpoints not possible (Parameters have been changed) |
440 | Station <StationName>: Measurement from measuring point <Number> outside of defined tolerance (dHz > <Value> oder dV > <Value> oder dSL > <Value>). Measured values will therefore not be taken over as the last measured values of the measuring point. |
441 | Station <StationName>: Measurement from measuring point <Number> outside of defined tolerance (dHz > <Value> oder dV > <Value>). Measured values will therefore not be taken over as the last measured values of the measuring point. |
442 | Station <StationName>:Measurement from measuring point <Number> outside of defined tolerance (Delta Raumstrecke > <Value>). Measured values will therefore not be taken over as the last measured values of the measuring point. |
450 | Station <StationName>: At least 3 fixpoints required (only <Quantity> found) |
451 | Station <StationName>: Fixpoints without Cartesian coordinates found (<Quantity>) |
452 | Station <StationName>: Polar coordinates required for at least 2 fixpoints (<Quantity> found) |
453 | Station <StationName>: Fixpoint <Number> will be used for new stationing |
454 | Station <StationName>: The polar coordinates of fixpoint <Number> are calculated using the Cartesians coordinates. |
470 | Station <StationName>: Weather data measurement |
471 | Station <StationName>: Weather data measurement failed (Connection to <Number> failed) |
472 | Station <StationName>: Weather data measurement failed (Data request from <Number> failed) |
473 | Station <StationName>: Weather data measurement failed (old values used) |
475 | Station <StationName>: Air pressure measurement without valid value (Channel <Number>) |
476 | Station <StationName>: Temperature measurement without valid value (Channel <Number>) |
477 | Station <StationName>: Wet-bulb temperature without valid value (Channel <Number>) |
|
|
500 | Station <StationName>: Remote control started |
501 | Station <StationName>: Remote control ended |
502 | Station <StationName>: No remote control possible, when time program is active |
505 | Station <StationName>: Error during remote control in Phase 1: <ErrorNotification> |
506 | Station <StationName>: Error during remote control in Phase 2: <ErrorNotification> |
507 | Station <StationName>: Error during remote control in Phase 3: <ErrorNotification> |
510 | Station <StationName>: Remote control canceled |